What was found
DURING BIRDSTRIKE INSPECTION FOUND THE FOLLOWING DAMAGE: A DENT JUST FORWARD OF FRAME 3 AND JUST BELOW STRINGER 20R. THE DENT MEASURES 3.5 INCHES WIDE AND 3.5 INCHES LONG AND IS 0.10 INCH DEEP. IT IS 0.125 INCH FROM THE RIVETS ON FRAME 3 AND 4.25 INCHES FROM THE RIVETS IN STRINGER 20R. THERE IS A CREASE IN THE SKIN ON THE FORWARD SIDE OF FRAME 3. *** THIS HAS BEEN DETERMINED TO BE A MAJOR REPAIR PER GMM 3-26, FORM M-337 WILL BE REQUIRED. (FILED- CLOSED) PERFORMED DOUBLER REPAIR AT FWD FUSELAGE FRAME 3 BETWEEN STGR26R AND STGR28R IN REFERENCE TO ERJ175 SRM 53-10-01 AND ETD2022-170-009232 REV.:/ DATED MARCH 15, 2022. / - REFER TO CP 24494398 FOR EDDY CURRENT INSPECTION OF REPAIR CUT-OUT. / - REFER TO CP 24501600 FOR SURFACE FINISH. / - REFER TO CP 24495802 FOR PRESSURIZATION CHECK.