What was found
*CORROSION ON FLOOR SUPPORT STRAP AT FS 559.00 BETWEEN RBL 9 €“ RBL 18 (C-CHECK RO 3-25-22) REMOVED CORROSION ON FLOOR SUPPORT STRAP AT FS 559.00 BETWEEN RBL 9 €“ RBL 18 IAW CRJ200 SRM 51-21-06. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED NEW FLOOR SUPPORT STRAP AT FS 559.00 BETWEEN RBL 9 €“ RBL 18 REF CRJ200 SRM 51-42-06 AND DWG 601R31025 REV-N. COMPLED WITH TASK CARD 51-900-1003-SKY.