What was found
POST REMOVAL INSP- FOUND FORWARD WEB CRACKED UNDER AFT SERVICE DOOR THRESHOLD BEAM UPON REMOVAL (C-CHECK RO 7/24/2022) REMOVED AND EDGE BLENDED FORWARD WEB CRACKED UNDER AFT SERVICE DOOR THRESHOLD BEAM L=.915" W=.130" MAINTANING AT LEAST 2D EDGE DISTANCE FROM ANY FASTENER REINSTALLED WEB REF SRM 51-40-08. WITHI LIMITS REF SRM 51-75-16. RESTORED SURFACE PEOTECTION REF SRM 51-23-04, 51-23-05, 51-23-06