As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PAX DOOR INTERNAL STRUCTURE AFT LOWER INTERCOASTAL DD1 IS BENT. MARKED (C-CHECK RO 8/15/2022) REMOVED AND REPLACED BENT AFT LOWER INTERCOASTAL DD1 WITH A NEW SERVICEABLE UNIT REF CRJ200 SRM 51-42-06 AND DWG 601R31702 REV N. LEAK CHECK GOOD. SEE CONTINUATION CARD FOR DETAIL. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY.