What was found
FS280 BEAM/FLOOR SUPPORT BEAM CLIP, OB, RBL9, IS CRACKED IN RADIUS, UPPER END. (FILED CLOSED) FABRICATED BEAM CLIP PER SRM 53-21-43. REMOVED AND REPLACED FS280 BEAM/FLOOR SUPPORT BEAM CLIP, OB, RBL9, IAW SRM 51-42-21
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS280 BEAM/FLOOR SUPPORT BEAM CLIP, OB, RBL9, IS CRACKED IN RADIUS, UPPER END. (FILED CLOSED) FABRICATED BEAM CLIP PER SRM 53-21-43. REMOVED AND REPLACED FS280 BEAM/FLOOR SUPPORT BEAM CLIP, OB, RBL9, IAW SRM 51-42-21