What was found
L/H SIDE INSIDE PRESSURE FLOOR SILL FROM FS 409+128 TO FS 559.0 HAS AREAS OF CORROSION (C-CHECK RO 11/10/2022) BLENDED CORROSION WITHIN LIMITS ON L/H PRESSURE FLOOR SILL FROM FS 409+128 TO FS 559.0 REF REO 601R-53-41-666 REV. -C DATED 2012-11-06, AND REO 601R-53-41-3076 REV-- DATED 2022-09-27. / COMPLIED WITH ALL STEPS OF REO 601R-53-41-666 REV C DATED 2012-11-06 AND REO 601R-53-41-3076 REV-- DATED 2022-09-27 RESTORED FINISH, SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH TASK CARD 51-900-1002-SKY