What was found
FS 460 RBL 9.0 THERE IS A SUSPECT CRACK ON UPPER RADIUS OF CASTING ON PRESSURE FLOOR BEAM. (C-CHECK RO 11/10/2022) LOCATED, DRILLED AND INSTALLED NEW 600-31068-19 FLOOR SUPPORT FITTING REF CRJ 200 SRM 51-42-21 CRJ-200 SRM 51-42-22 AND CRJ 200 SRM 51-42-06 WITH DRAWINGS 601R31118 REV L AND 601R31172 REV E FOR FASTENERS. COMPLIED WITH 51-900-1003-SKY.LEAK CHECK GOOD AT THIS TIME / REO # 601R-53-41-3072, REV-- DATE 2022-09-26