What was found
FOUND CRACK IN FITTING FORWARD OF AFT EQUIPMENT DOOR OPENING AT APPROX ST672 HAS A CRACK IN IT THAT IS APPROX 1/2-3/4" DEEP. COMPLIED WITH TEMPORARY REPAIR PER REO REO 601R-53-61-7321 REV-- DATE 2020-02-21. PERMANENT REPAIR DUE WITHIN 4500 FLT HRS BY 50119.4 TAT. COMPLIED WITH PERMANENT REPAIR FOR CAP ANGLE OF FRAME AT FS672.20 AND AT STR27 PER REO 601R-53-61-7879 REV-. COMPLIED WITH TASK CARD 51-900-1003-SKY.