What was found
PAX DOOR INTERNAL STRUCTURE CLEAT AT STA. FS 313.56, DATUM DD4 IS CORRODED. MARKED (C-CHECK RO 11/12/2022) PAX DOOR INTERNAL STRUCTURE CLEAT AT STA. FS 313.56, DATUM DD4 FOUND TO BE OUT OF LIMITS OF CRJ200 SRM 52-00-00, REMOVED AND REPLACED IAW CRJ200 SRM 51-42-06. AND DWG 601R31702 REV -N, COMPLIED WITH TASK CARD 51-900-1003-SKY