What was found
L/H FLOOR SILL SHOWS EVIDENCE OF CORROSION IN MULTIPLE AREAS (MARKED) (C-CHECK RO 2/26/2023) CORROSION BLENDED OUT IN MARKED AREAS AND FOUND WITHIN LIMITS PER REO 601R-53-41-666 REV. -C, DATED 2012-11-06. 2EA FASTENERS WERE REPLACED WITH ALTERNATES AT FS473.15+2, LBL37 REF REO 601R-53-41-3120 REV. --, DATED 2023-01-31. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY AND FORM M-337. LEAK CHECK GOOD. SEE CONTINUATION FOR DETAILS OF WORK ACCOMPLISHED.