What was found
AFT EQUIPTMENT BAY JUST AFT OF PRESSURE BULKHEAD LH OUTBD BETWEEN FS 621-625 APPROX WL 106 CLIP FOR INTERCOSTAL IN LINTEL REPAIR HAS A POSSIBLE CRACK (C-CHECK RO 3/7/2023) REMOVED AND REPLACED CLIP REF CRJ 200 SRM 51-42-06, AND DWG 601-35012 , REV-D, AFT EQUIPTMENT BAY JUST AFT OF PRESSURE BULKHEAD LH OUTBD BETWEEN FS 621-625 APPROX WL 106 COMPLIED WITH TASK CARD 51-900-1003-SKY AND M-337 FORM