What was found
TRANSFER FROM EAML 1075549 : DURING THE REPLACEMENT OF SIDE WINDOW, FOUND A CRACK ON LHS SIDE POST (DWG 601R33223, REF) AT TOP BOLT HOLE. THE CRACK GOES THROUGH THE FULL THICKNESS OF THE WEB (0.625", REF) FROM FWD SURFACE TILL THE BARREL NUT HOLE (0.500", REF). LOWER PORTION OF THE WEB BELOW BARREL NUT HOLE & INBOARD FLANGE ARE NOT CRACKED. (FILED CLOSED)REMOVED AND REPLACED DAMAGED LT SIDE WINDOW POST IN REF. TO CRJ 700 SRM 51-10-06, 51-42-20 AND 51-77-00 ALSO IN REF. TO TASK CARD 51-900-1002-SKY AND FORM M-337. SEE CP 26167896 FOR PRESSURIZATION CHECK.