What was found
LEFT FUSELAGE STRUCTURE DENTED BY FS169.00 IN BETWEEN RADOME AND ACCESS PANEL 121 AL HAS BEEN EVALUATED AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-31. REFERENCE FOR CP 26143452 FOR INITAL DISCREPANCY. THIS IS A "MAJOR REPAIR". FORM M-337 INITIATED. (FILED CLOSED)REMOVED AND REPLACED THE FOLLOWING STRUCTURAL COMPONENTS, SKIN, SPLICE ANGLE, DOOR LAND PER DWG. 600-33052 REV F. DWG. 601R33010 REV J. SRM 51-21-00 SRM 51-25-00 SRM 51-40-11 SRM 51-42-06 SRM 51-42-10 SRM 51-42-20 SRM 51-42-21SRM 51-45-00. ALSO COMPLIED WITH TASK CARD 51-900-1003-SKY STRUCTURAL MAJOR REPAIR. FORM M-337 COMPLETED.ALL WORK WAS PERFORMED IN CONJUNCTION WITH MHIRJ MOBILE REPAIR TEAM. SEE ATTACHED FOR AIRCRAFT STATEMENT OF WORK.