What was found
R/H FLOOR BEAM AT RLB9 BETWEEN FS559.00 TO FS559.00+80 SEVERAL AREAS HAS CORROSION (MARKED) (C-CHECK RO 5/15/2023) REMOVED AND REPLACED THE R/H FLOOR BEAM UPPER CAP SUPPORT ASSY. AT RBL BETWEEN FS 559.00 AND FS 574.00 REF, CRJ-200 SRM 51-42-21 REV 39 MAR10/21, CRJ-200 SRM 51-42-06 REV 39 MAR10/21 DWG# 601R31119 REV H, DWG# 601R31005 REV B, DWG# 601R31030 REV-P AND REO 601R-53-51-663 REV--, DATED 2023-04-28. COMPLIED WITH ALL STEPS. COMPLIED WITH 51-900-1003-SKY (CL600-2B19) STRUCTURAL MAJOR REPAIR (**RII**). SEE CONTINUATION FOR DETAILS.