What was found
R/H FLOOR BEAM AT RLB9 BETWEEN FS409.00 TO FS409.00+128 SEVERAL AREAS IS CORROSION (MARKED) (C-CHECK RO 5/15/2023) REPLACED R/H FLOOR BEAM AT RLB9 BETWEEN FS409.00 TO FS409.00+128 REF. REO 601R-53-31-1275 REV-- DATED 2023-04-14 & DWG 601R31117 REV E, 601R31030 REV P & 601R31005 REV B. COMPLIED WITH SKYCARD 51-900-1003-SKY.