What was found
STGR22L HAS CORROSION AT FS589-FS605 2EA AREAS (MARKED) (C-CHECK RO 9/13/2023) REMOVED CORROSION AT STGR22L FS589-FS605 2EA AREAS REFR CRJ200 SRM 51-21-06. BLEND #1 FOUND TO BE WITHIN LIMIT AND BLEND #2 FOUND TO BE OUT OF LIMITS REF CRJ 200 SRM 53-00-00. REMOVED DAMAGED STRINGER AND INSTALLED WITH NEW STGR22L SPLICE AND FORMED SECTIONS P/N: S6957-12 AND S6957-11 WITH RADIUS FILLERS REF CRJ-200 SRM 53-00-03. LEAK CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY. SEE CONTINUATION CARD FOR DETAILS.