As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INTERIOR FS409.0+128-FS559.0 RIGHT SILL HAS CORROSION IN VARIOUS AREAS (C-CHECK RO 9/26/2023) REPAIRED CORROSION ON THE R/H FLOOR SILL PANEL BETWEEN FS409.00+128 TO FS559.00 AT VARIOUS LOCATIONS ( 9 EA.) REF REO 601R-53-41-666 REV-C, DATED 2012-11-06. COMPLIED WITH ALL STEPS. COMPLIED WITH 51-900-1003-SKY (CL600-2B19) STRUCTURAL MAJOR REPAIR (**RII**). SEE CONTINUATION FOR DETAILS.