What was found
AFT WET AREA L/H FLOOR BEAM CORRODED APPROX. 2.5 INCHES OF FRAME 84 AT SEAT TRACK AND OUTBOARD FLANGE (C-CHECK RO 1/7/2024) PERFORMED PERMANENT DOUBLER REPAIR ON LH INBD FLOOR BEAM SEAT TRACK AT FR 84-85. REF. ETD2023-170-032099. SEE CONTINUE CARD FOR FURTHER WORK PERFORNED. WEIGHED REPAIR PARTS FOR LH INBD FLOOR BEAM SEAT TRACK FR 84-85 PERMANENT REPAIR. MEASURED 156.1 GRAMS. REF. GMM CH. 3 SEC. 12, 1.1.3. THIS REPAIR DOES NOT AFFECT WEIGHT AND BALANCE OF ACFT.