What was found
SIGNS OF CORROSION ON FLOOR SUPPORT AT FS409.00+8 AND LBL9 AROUND FASTENER HOLE, NEEDS EVAL (FILED CLOSED)CORROSION REMOVAL FOUND TO BE OUT OF LIMITS ON FLOOR SUPPORT AT F.S.409.00+8 LBL9 IAW CRJ200 SRM 53-00-00, PERFORMED SPECIAL DETAILED ET/UT INSPECTION OF BLENDED CORROSION ON FLOOR SUPPORT AT F.S.409.00+8 LBL9, LOWEST REMAINING MATERIAL THICKNESS IS .038, NO DEFECTS NOTED AT TIME OF INSPECTION,REMOVED AND REPLACED FLOOR SUPPORT FROM F.S.409.00-F.S.409.00+112 LBL9 IAW CRJ200 SRM 51-42-06, 51-42-21 AND 51-42-34, RE-INSTALLED SEATTRACK AT F.S.409.00 - F.S.409.00+112 LBL9 IAW CRJ200 SRM 51-41-02