What was found
CORROSION ON WING TO FUSELAGE FITTING OUTER SURFACE AT FS 473Â (C-CHECK RO 04/30/2025)CLEANED UP CORROSION, PERFORMED HFEC NDT INSPECTION, NO CRACKS NOTED, PERFORMED ROTO PEEN ON BLENDED AAREAS AND RESTORED AREAS TO SURFACE FINISH REF. TO MHIRJ CRJ200 SRM 51-21-06 PARA.5D, NDTM 51-20-06 PT6, SRM 51-24-11 AND REO 601R-57-21-3881 REV. -- DATED: 2025-01-02