What was found
RH AFT LWR FUSELAGE AT FR1031.00 10 INCHES AFT BETWEEN STR24R AND 25R THERE IS A DENT (C-CHECK RO 8/22/2024) EVALUATED AND DRESSED BACK DENT ON R/H AFT LOWER FUSELAGE AT FR 1031.00+10 INCHES AFT BETWEEN STR 24R AND 25R. NO OIL CAN CONDITION PRESENT AT TIME OF THE DRESS BACK, NO INTERNAL STRUCTURE DAMAGE NOTED. DIMENTIONS AT THE REWORK AREA: L=1.000" W=0.800" D=0.005" NF= 0.850". IS FOUND WITH IN LIMITS IAW REO 670-51-00-085 REV "A" DATED: 2017-08-23, MHIRJ REO 670-53-61-2314. REV. --. DATE: 2024-07-14. SRM 53-61-01, AMM 38-32-15, AMM 53-00-47,AMM 38-12-35,AMM 38-12-23. NDT PERFORMED BY BARON NDT LLC, FAA CRS# 5NDR545D REPORT# S070224-10, P.O.# 172794 DATE OF THE INSPECTION 02 JUL 24. SEE REPORT FOR DETAILS. CALIBRATED TOOL: DEPTH GAUGE AV-7277 DUE DATE: AUG 24,