What was found
DURING THE AUDIT OF 1C TASK CARD 53-280-300, INTERNAL ZONAL INSPECTION OF THE CARGO COMPARTMENT, IT WAS NOTED THAT THERE IS EVIDENCE OF MULTIPLE FASTENER CHAFES/CONTACT ON THE FWD SIDE OF THE FS 621 BULKHEAD. PLEASE INVESTIGATE AND REPAIR AS REQUIRED. (C-CHECK RO 5/13/2024) PERFORMED REPAIR ON FS 621 FWD SIDE BULKHEAD PER REO 601R-53-61-8181. REV. --. DATE: 2024-04-01. NDT PERFORMED BY BARON NDT, LLC, FAA CRS# 5NDR545D. REPORT # S040124-2. CRJ-200 SRM 57-71-19 AND CRJ-200 SRM 51-42-06. CALL TOOLS AV-7277 CAL AUG 2024, AV-7806 CAL AUG 2024