As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH FWD EQUIPMENT COMP THE FLOOR PANEL IS CRACKED AT FR193 (C-CHECK RO 11/16/2023) PERFORMED DOUBLER REPAIR AT LH FWD EQUIPMENT COMP. FLOOR PANEL FR 193 . PERFORMED NDT INSPECTION ON CUTOUT BY BARON NDT LLC FAA CRS#5NDR545D REPORT #S101923-1 WITH NO DEFECTS NOTED IAW REO 601R-53-11-3897.