What was found
ADG STOW PUMP MOUNTING PLATE CRACKED (C-CHECK RO 8/22/2024) FABRICATED AND INSTALLED REPAIR ON ELECTRICAL BAY FLOOR AT ADG STOW PUMP MOUNTINTING, PERFORMED NDT INSPECTION BY BARON NDT LLC FAA CRS# 5NDR545D , REPORT# S071224-1, P.O# 172794 DATE OF INSPECTION: 12-JUL-2024, NO DEFECTS NOTED AT TIME OF INSPECTION, FOUND TO BE WINTH IN LIMITS IAW BOMBARDIER REO 670-53-11-509 REV-E DATE: 2018-02-08, MHIRJ REO 670-53-11-1984 REV--(P1) DATE: 2024-07-02, MHIRJ REO 670-53-11-1984 REV--(P2) DATE: 2024-07-09, MHIRJ REO 670-53-11-1984 REV-- DATE: 2024-07-20 AND IAW CRJ 700 SRM 51-42-06, SRM 51-21-11, SRM 51-25-06, SRM 51-40-11 AND AMM 20-70-00 AND TASK CAR 51-900-1002-SKY.CAL TOOL USED ID: DIGITAL CALIPER ID: AV-7803 CAL DUE: JAN-2025 DIGITAL SCALE ID: AV-8473 CAL DUE: AUG-2024