What was found
CORROSION ON STGR 26L BETWEEN FS 1000.00 - 1031.00 (C-CHECK RO 7/9/2024) REMOVED CORROSION ON STGR26L BETWEEN FS1000.00-FS1031.00 AND FOUND OUT OF LIMITS PER CRJ900SRM 53-61-03-101-003-A02. PERFORMED STGR SPLICE REPAIR STGR26L FS977.00-FS1031.00 PER CRJ900SRM 53-00-03-201-001-A02 USING ALTERNATE P/N MM670-35151-035 PER REO 690-53-61-1405 REV -- DATE 2024-06-04. LEAK CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. COMPLIED WITH FORM M-337. SEE CONTINUATION FOR DETAILS.