What was found
BLENDS #6 AT STGR18R FS661 +54 FOUND TO BE OUT OF LIMITS REPAIR STGR18R EVALUATED ON JOB : HN00159277 (C-CHECK RO 7/9/2024) INSTALLED FABRICATED REINFORCEMENT ANGLE -4 FROM S6144-4 PO# 5-24686 , -5 RADIUS BLOCK FROM 2024T3 .050" PO# T-67874 AND LAMINATE SHIM FROM AMS-DTL 22499 COM 1 TYPE 1 CLASS 1 PER REO 690-53-31-840 REV -- DATED 2024-06-05 IN ITS ENTIRETY. LEAK CHECK GOOD. COMPLIED WITH 51-900-1002-SKY.