What was found
LH INBD FLAP VANE CHAFFED AT INBD HINGE LOCATION (C-CHECK RO 10/6/2024) (FILED CLOSED)REMOVED AND REPLACED LH INBD FLAP VANE. NDT PERFORMED BY BARRON NDT LLC, FAA CRS #5NDR545D, REPORT #S072924-5 P.O. #173177 DATE OF INSPECTION 29JUL2024, SEE REPORT FOR DETAILS. IAW CRJ700 SRM 57-52-01, SRM 51-42-10, SRM 51-40-11, SRM 51-21-11, SRM 51-25-06, AND SRM 51-25-01