What was found
CORROSION ON PRESSURE FLOOR SILL AT FS 461.00 ON RBL 36.00 (FILED - CLOSED) REPAIRED CORROSION DAMAGE ON PRESSURE FLOOR SILL AT FS 461.00 ON RBL 36.00 WITH REFERENCE TO REO 601R-53-41-666 REV -C DATED 2012-11-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND WITHIN LIMITS OF REO 601R-53-41-666. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND PART 6 53-00-096 WITH NO DEFECTS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS.