What was found
PUNCTURE ON THE R/H FUSELAGE BETWEEN FS 559+96 AND 559+112 AND BETWEEN STGR 16R AND 17R MEASURING APPROX 3.5" H X 4" L. THIS IS CLASSIFIED AS A MAJOR REPAIR. FORM M-337 INITIATED. (FILED CLOSED) PERFORMED PERMANENT REPAIR ON R/H FUSELAGE BETWEEN FS 559+96 AND 559+112 AND BETWEEN STGR 16R AND 17R IAW REO 601R-53-51-679 REV -- DATED 2024-08-13.. PERMANENT REPAIR COMPLETED BY MHIRJ MRT AS STATED IN THE STATEMENT OF WORK. COMPLIED WITH STRUCTURAL MAJOR REPAIR TASK CARD 51-900-1003-SKY. COMPLETED FORM M-337. A/C OKAY FOR SERVICE AT THIS TIME.REFERENCE CP 28664057 FOR STEP 3 OF REO 601R-53-51-679, REFERENCE CP 28664063 FOR STEP 4 OF REO 601R-53-51-679. REFERENCE CP 28672239 FOR PRESSURIZATION CHECK OF REPAIRS.