As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND ELONGATED HOLES ON PANEL 511AZ AND ASSOCIATED STRUCTURE (MARKED) CAMP 28489966 (C-CHECK RO 8/24/2024) PERFORMED REPAIR FOR ELONGATED FASTENER HOLES TO LH COLLECTOR TANK PANEL AND ACCESS PANEL 511AZ IAW ALL STEPS OF REO 690-57-11-127 REV--, DATED 2024-07-30. COMPLIED WITH TASK CARD 51-900-1002-SKY. FREEZE PLUG FOR OPENED HOLE, NO WEIGHT CHANGE