What was found
AVIONICS BAY DOOR SURROUND HAS WEAR ABRASION ALONG ENTIRE PERIMETER OF DOOR SURROUND (MARKED) (C-CHECK RO 9/15/2024) BLENDED DAMAGE ON AVIONICS BAY DOOR SURROUND ENTIRE PERIMETER, REMAINING THICKNESS = 0.113", MATERIAL REMOVED 0.007", ALLOWABLE MAX DEPTH = 0.040", REMAINING THICKNESS = 0.080" IS FOUND WITHIN LIMITS, STEPS 1, 2, 3 AND STEP 4(LESS THAN .015" MATERIAL LOSS "NO LEAK TEST REQUIRED) C/W REF. REO 690-53-21-032, REV. --, 2008-03-07. COMPLIED WITH SKYWEST M-337 FORM AND ALSO COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.