What was found
UPON REMOVAL OF STUCK SCREWS, FOUND 2EA MISDRILLED HOLES IN PANEL 591FT STRUCTURE. CAMP 28475622 (C-CHECK RO 9/15/2024) REPAIRED 2EA ELONGATED HOLES TO LH OUTBOARD FLAP LOWER DOUBLER BETWEEN FLAP STA 209.390 - FLAP STA 226.150 PER REO 690-57-53-158 REV -- DATE 2024-08-08 STEP 1 THRU 14.COMPLIED WITH 51-900-1002 SKY.