What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA58215-601R-53-21-3299 N986SW MXCODEID51600-PR - FUSELAGE BELOW THE SERVICE DOOR CUTOUT HAS 1EA MIS DRILLED HOLE REQUIRES EVAL CORRECTIVELY REPAIRED MISSED DRILLED HOLE WITH PLATE SUPPORT IAW BOMBARDIER REO 601R-53-21-3299-REV B , 3/31/2020. TEMPORARY REPAIR VALID FOR 6000 FLIGHT HOURS., PART NUMBER: - , SERIAL NUMBER: 7967, POSITION: (C-CHECK RO 9/24/2024) COMPLIED WITH PERMANENT REPAIR OF 1 EA. MIS-DRILLED HOLE ON FUSELAGE BELOW SERVICE DOOR CUT-OUT REF REO 601R-53-21-3699 REV --, DATED 2024-09-07. COMPLIED WITH ALL STEPS. COMPLIED WITH TASK CARD 51-900-1003-SKY. SEE CONTINUATION FOR DETAILS. LEAK CHECK GOOD.