What was found
PERFORM STRINGER REPAIR AT STGR 19R FS501-FS517 DUE TO CORROSION. (C-CHECK RO 7/9/2024) : EVALUATED DAMAGE ON STGR19R BETWEEN FS501.00 AND FS517.00 ORIGINAL THICKNESS IS .080 PER DWG # SH690-33151 REV -B ,MATERIAL LOSS IS .048 AND REMAINING THICKNESS IS 0.032 FOUND TO BE OUT OF LIMIT PER CRJ 900 SRM 53-31-03-101-004-A04REPAIRED PER CRJ900 SRM 53-00-03-201-001-A02 PERMANENT REPAIR SOLUTION IICOMPLIED WITH PRESSURE CHECK, CHECK GOOD COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY