What was found
CORROSION ON FRAME FLANGE ON THE FWD SIDE OF FS 559.00 +112 BETWEEN STGR 26L AND STGR 26R (FILE CLOSED) COMPLIED WITH REO 601R-53-51-698 DATED: 2024-12-07 REV-- REMOVED RIVETS AS NEEDED AND BLENDED SURFACE CORROSION ON FWD SIDE OF FRAME FLANGE AT FS559.00 + 112 BETWEEN STGRS 26L AND STGR 26R WITH REFERENCE TO SRM 51-42-06 AND SRM 51-21-06. PERFORMED UT THICKNESS MEASUREMENT OF BLEND WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF SRM 53-61-15 AND SRM 53-00-00. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 AND NDTM PART 6 53-00-097 WITH NO CRACKS FOUND. INSTALLED RIVETS WITH REFERENCE TO SRM 51-42-06 AND REO 601R-53-51-698 REV "--" DATED 2024-12-07. RESTORED FINISH AND APPLIED CIC WITH REFERENCE TO SRM 51-21-16 AND SRM 51-21-11. COMPLETED CORROSION FINDINGS REPORT. COMPLIED WITH TASK CARD 51-900-1003-SKY AND COMPLETED FORM M-337. SEE CHILD CAMP FOR LEAK CHECK.