What was found
CORROSION FOUND ON FRAME ATTACH FLANGE AT FS 501 OUTBOARD OF STR25L CAMP 29320788 (C-CHECK RO 2/26/2025) REMOVED AND INSTALLED NEW SECTOR FRAME AT FS501 OUTBOARD STGR 25L REF-CRJ-900 SRM 51-42-06-001-001 A01 AND DWG SH690-33750 REV AF. LEAK CHECK GOOD.COMPLIED WITH TASK 51-900-1002-SKY