What was found
FS280 FLOOR SUPPORT ANGLE BETWEEN LBL9 AND RBL9 HAS MULTIPLE LOCATIONS OF CORROSION. (C-CHECK RO 04/26/2025) BLENDED OUT CORROSION ON FS280 FLOOR SUPPORT ANGLE BETWEEN LBL9 AND RBL9. REF. CRJ900 SRM 51-21-06-001-001-A01.FOUND OUT OF LIMITS. REF. CRJ900 SRM 53-11-43-001-001-A01. REMOVED AND INSTALLED NEW FS280 FLOOR SUPPORT ANGLE BETWEEN LBL12 AND RBL12. REF. CRJ900 SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG# CC670 33052 REV. G..COMPLIED WITH 51-900-1002-SKY