What was found
FS847+32 FRAME ATTACHED FLANGE IS CORRODED BETWEEN STR 26L & 26R (C-CHECK RO 04/26/2025)REPLACED LOWER FRAME SEGMENTWHERE CORRODED AT F.S. 847+16 WITH SPLICE REPAIR OF NEW FRAME SEGMENT BETWEEN STGR 25L-25R, REF CRJ 900 SRM 53-00-06-201-001-A03 AND CRJ 900 SRM 51-42-02-001-001-A01 COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY (CL600-2D24) STRUCTURAL MAJOR REPAIR COMPLIED WITH DIGITAL COPY OF SKYWEST FORM M-337 (ATTACHED). ALL CHECKS GOOD.