What was found
RH WING, OTBD FLAP VANE MOUNT FITTINGS SHOW CHAFFING AND WEAR ALONG THE LOWER EDGE, AT WS 171, 189, 235, 280, 296, (5EA FITTINGS) (C-CHECK RO 04/30/2025) COMPLIED WITH REO 601R-57-53-195 DISPOSITION FOR WEAR DAMAGE ON O/B FLAPS BUJTE DOOR CAMS AND RIB FITTINGS. SEE ATTACHED RS-01 FOR DETAILS.ACCOMPLISHED OPS AND RIG CHECK ON R/H O/B FLAP BUTR DOOR SEE ATTACHED RS-01 ITEM 7 FOR DETAILES