Service difficulty report · Sensor · Cndair CL6002C10

Difficulty date
May 26, 2025
Submitted
May 27, 2025
Operation
Air carrier
Aircraft
N766SK
Make and model
Cndair CL6002C10
Aircraft serial
10232
Aircraft time
48,455 hours, 32,237 cycles
Part
Sensor
Condition
Faulted
Location
Zone 700
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

D:LEFT BRAKE SENSOR ON BTMS ERADIC TRIGGERING WARNING MESSAGE MULTIPLE TIMES.C:MEL 32-46-1DCAT C DUE 06/05/25**ODI / RTF ****SMOD APROVAL**LEFT BRAKE SENSOR ON BTMS ERADIC TRIGGERING WARNING MESSAGE MULTIPLE TIMES. (FLIGHT 4966 - FILED CLOSED)MAY 26, 2025 STATION: DFW--DEFERRED LH OUTBOARD MLG BRAKE TEMP SENSOR IN REF TO MEL 32-46-1D, LEFT OUTBOARD BRAKE TEMP SENSOR (TC09) IS DISCONNECTED, MX ACTIONS COMPLIED WITH, PLACARDS INSTALLED MAY 27, 2025 STATION: SBN -- FOUND B1-007475 TROUBLESHOT PER CRJ 700 FIM 32-46-01. FOUND LEFT OB BRAKE TEMP SENSOR BROKEN OFF FROM THE BASE OF THE ROD. CHECKED WIRING BETWEEN LH OB BRAKE TEMP SENSOR AND ASCU. FOUND OKAY, CLEARNED OUT DEBRIS FROM SENSOR CANON PLUG. #1 BRAKE DOES NOT APPEAR TO HAVE SIGNS OF OVER HEATING. REMOVED AND REPLACED LH OB BRAKE TEMP SENSOR IN ACCORDANCE WITH CRJ 700 AMM 32-46-01. OPS CHECK GOOD. DMI CLEARED AND PLACARDS REMOVED.SMOD APPROVAL RECEIVED AT 738EST. BY BRANDON MILLER.