What was found
ENGINE SUPPORT BEAM LBL27.50 CLOSE OUT ANGLE AT FS625.30 & WL119.12 HAS AN INDICATION .3" LONG BY 100% FSH PROPERGATING FROM THE UPPER FASTENER HOLE. FAILED NDT INSPECTION. (C-CHECK RO 05/27/2025)REMOVED UNSERVICEABLE LH ENG SUPPORT BEAM CLOSE OUT ANGLE (P/N: 601-35006-157SB) AT LBL27.50, FS625.30 AND LOCATED, DRILLED, AND INSTALLED NEW SERVICEABLE LH ENG SUPPORT BEAM CLOSE OUT ANGLE (P/N: 601-35006-157SB) AT LBL27.50, FS625.30 IAW CRJ200 SRM 51-40-11, 51-42-06, AND 51-42-21. REFERENCE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED. COMPLETED TASK CARD 51-900-1003-SKY AND ATACHED COMPLETED FORM 337. NO WEIGHT CHANGE.