What was found
LH WING FUEL CELL ACCESS PANEL (510AB) LANDING HAS TWO SPOTS OF MINOR CORROSION AT THE 12 O'CLOCK & 3 O'CLOCK POSITION, MEASURING APPROX 2.75 INCHES AND 3 INCHES RESPECTIVELY. (C-CHECK RO 06/12/2025)REPAIRED LH WING FUEL CELL ACCESS PANEL LANDING(510AB) LANDING AT THE 12 O'CLOCK & 3 O'CLOCK POSITION WITH REFERENCE TO REO 601R-57-21-030 REV "L" DATED 2014-02-05. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. PERFORMED UT REMAINING THICKNESS INSPECTION WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF 601R-57-21-030 REV. -L, DATED 2014-02-05. PERFORMED ROTO PEEN WITH REFERENCE TO REO 601R-57-21-030 REV. -L, DATED 2014-02-05. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLETED M-337. COMPLETED CORROSION FINDINGS REPORT.