Service difficulty report · Wire Harness · Cndair CL6002D24

Difficulty date
July 23, 2025
Submitted
July 24, 2025
Operation
Air carrier
Aircraft
N817SK
Make and model
Cndair CL6002D24
Aircraft serial
15107
Aircraft time
41,361 hours, 27,615 cycles
Part
Wire Harness
Part number
SH67059062003SW
Condition
Faulted
Location
Zone 800
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON CLIMB OUT ABOUT 6000 FEET MSL PASSENGER DOOR WARN MESSAGE PLUS PROX SYSTEM FAULT 1 STATUS MESSAGE CAME ON (FLIGHT 4818) MDC SHOWS AFT CARGO DOOR PROX SENSOR PX102 WENT OPEN, THEN SHORT. TWO MINUTES LATER, SEVERAL MCD PROX SENSORS FAILED OPEN. THIS WAS FOUND TO BE CAUSED BY ALL THREE WIRES TO AFT CARGO DOOR HARNESS BROKEN AT PX102P1 AND WIRES TOUCHING FRAME OF AIRCRAFT. THIS IN TURN, CAUSED CIRCUIT BREAKERS CB2 R8 AND CB2 R9 TO POP SO MCD SECTION OF PSEU FAILED. REMOVED AND REPLACED AFT CARGO DOOR PROX SENSOR HARNESS IAW AMM 52-70-02. RESET CIRCUIT BREAKERS CB2 R8 AND CB2 R9. PSEU OPS CHECKS GOOD IAW AMM 32-61-01. MCD AND AFT CARGO DOOR WARNING SYSTEMS OPS CHECK GOOD IAW AMM 52-70-00. PROX SYSTEM 1 FAULT NO LONGER PRESENT.