As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH AFT EMER EXIT DOOR, UPPER STOP ON THE DOOR, POSSIBLE CRACK IN THE DOOR FRAME (MARKED) (C-CHECK RO 02/01/2026)FLUORESCENT PENETRANT INSPECTED PER REF CRJ900 NDTM 51-20-008-230-A01. NDT FAILED. ENDS OF CRACK MARKED FOR REPAIR. SEE ATTACHED NDT-11REPAIRED CRACK LH AFT EMER EXIT DOOR, UPPER STOP ON THE DOOR PER GREO 670-52-21-103 REV -- 2024-11-06SEE CONTINUE CARD FOR DETAILS C/W SKYCARD 51-900-1000-SKY