What was found
RIGHT INBD FLAP LOWER SKIN BETWEEN FLS65.50-FLS75.60 AT TRAILING EDGE LIGHTNING STRIKE DAMAGE. PER REO 690-57-52-517 DATED 2025-04-07 REV TEMPORARY DISPOSITION FOR BLENDED LIGHTNING STRIKE DAMAGE ON RH INBD FLAP LOWER SKIN BETWEEN FLS65.50-FLS75.60 AT TRAILING EDGE. CUT AWAY DAMAGED SKIN RH INBOARD FLAP LOWER SKIN, DAMAGED CHANNEL, AND UPPER SKIN AS REQUIRED BY REPAIR CRJ 900 SRM 57-52-01-201-001-A01 FABRICATED REPAIR ITEMS WET ASSEMBLED ALL FABRICATED PARTS AND INSTALLED BLIND FASTENERS ON RH INBD FLAP LOWER SKIN BETWEEN FLS65.50-FLS75.60 AT TRAILING EDGE LIGHTNING STRIKE DAMAGE. REF CRJ 900 SRM 57-52-01-201-001-A01, COMPLIED WITH 51-900-1002-SKY.