What was found
LEFT WING FUEL CELL ACCESS PANEL LANDING HAS MULTIPLE AREAS OF MINOR SURFACE CORROSION. BLENDED CORRODED AREA OF LT WING FUEL ACCESS PANEL LANDING 510AB IAW REO 601R-57-21-030 REV. -L,. PERFORMED UT REMAINING THICKNESS INSPECTION WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF 601R-57-21-030 REV. -L, PERFORMED ROTO PEENING IN REF WITH REO 601R-57-21-030 REV. -L, APPLIED SURFACE FINISH AS REQUIRED PER REO. COMPLETED CORROSION FINDINGS REPORT. REFERENCE CP 30350391 FOR EDDY CURRENT INSPECTION.