What was found
CRACK FOUND IN ELECTRICAL BAY FLOOR PANEL (REF DWG 601R33101) AT FS 193.00 JUST BELOW AND OUTBOARD OF BRAKE ACCUMULATOR GUAGES. (C-CHECK RO 08/29/2025) REPAIRED CRACK IN ELECTRICAL BAY FLOOR PANEL AT FS 193.00 JUST BELOW AND OUTBOARD OF BRAKE ACCUMULATOR GUAGES IN REFERENCE TO REO 601R-53-11-4005 REV-- DATED 2025-07-22. PERFORMED EDDY CURRENT IN REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-96. NO CRACKS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLETED M-337.