As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND ON RBL 27 FLOOR BEAM CAP BETWEEN FS 559 AND FS 559+10 (C-CHECK RO 10/19/2025)REMOVED CORRODED SECTION AND REPAIRED IAW REO 601R-53-41-3351 REV -- DATED 2025-09-24. COMPLETED TASK CARD 51-900-1003-SKY AND ATTCHED COMPLETED FOR 337. WEIGH CHANGE NEGLLIGIBLE