As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE PERFORMING REINSPECT OF R/H PRESSURE FLOOR SILL, FOUND CORROSION AT PREVIOUS BLEND REPAIR AT APPROX. F.S. 530.50, R.B.L. 42.00 AROUND NUTPLATE LOCATION. (C-CHECK RO 10/19/2025)REMOVED CORROSION FROM RH FLOOR SILL AT FS 530 AND FOUND WITHIN LIMITS OF 601R-53-41-0666 REV C DATED 2012-11-06. COMPLETED TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED