What was found
MAIN AVIONICS BAY DOOR SURROUND STRUCTURE HAS PITTING AROUND THE PERIMETER OF THE LAND. (MARKED IN RED) (C-CHECK) REMOVED DAMAGE IN MAIN AVIONICS BAY DOOR SURROUND STRUCTURE IAW SRM 51-12-00-001-001-A01. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE AROUND DOOR CUT OUT IAW CRJ900 SRM 53-21-01-101-006-A04 AND CRJ900 SRM 53-21-01-001-006-A02. RECEIVED AND COMPLIED WITH REO 690-53-21-032, REV.--, DATED 2008/03/07COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY, STRUCTURAL MAJOR REPAIR.